Energy, Work and Power · Cambridge syllabus 1.7 · Lesson 6 of 6
Efficiency
Includes Supplement objectivesEfficiency is useful output energy divided by total input energy, or the corresponding power ratio. Multiply by 100 for a percentage. Insulation and reduced friction can increase the useful fraction.
By the end, you can
- Understand useful and wasted energy.
- Calculate efficiency. [Supplement]
- Express efficiency as a decimal or percentage. [Supplement]
- Identify methods of reducing wasted energy.
- Interpret Sankey diagrams, including transfers with several stages. [Supplement]
Efficiency
No machine transfers all of its input energy usefully. Some of the energy goes where you want it, the useful output, and the rest is wasted, usually by heating the machine and its surroundings, or as sound. A filament lamp is a striking example: most of the energy supplied to it heats the room, and only a small part leaves as light.
Efficiency measures the fraction that ends up where you wanted it: efficiency = useful energy output ÷ total energy input, and multiplying by 100% gives a percentage. The same ratio works with power: efficiency = useful power output ÷ total power input. A motor supplied with 500 J that delivers 350 J of useful work is 350 ÷ 500 = 0.70, or 70% efficient. A 60 W lamp that gives out 6 W of light is 6 ÷ 60 = 0.10, or 10% efficient. The wasted energy has not vanished — conservation of energy forbids that — it has been dissipated, mostly to the internal store of the machine and its surroundings.
Efficiency can never exceed 100% once every input is counted, and a claim that it does is a claim that energy has been created. It can never quite reach 100% either, because some waste is unavoidable in any real machine.
Improving efficiency means attacking the wasted pathways directly: lubricate moving parts to reduce friction, insulate to reduce unwanted heating, streamline to reduce air resistance, and replace filament lamps with LEDs, which waste far less energy by heating.
- efficiency = useful energy output ÷ total energy input
- The fraction of the energy supplied that ends up where you wanted it.Multiply by 100% for a percentage.
- efficiency = useful power output ÷ total power input
- The same fraction worked out from powers instead of energies.Multiply by 100% for a percentage.
Worth remembering
- Efficiency = useful output ÷ total input, as a decimal or × 100% for a percentage.
- Works with energy or with power.
- Never above 100%, and never quite at it; the difference is dissipated, not destroyed.
- Reduce waste: lubricate, insulate, streamline.
Sankey diagrams
A Sankey diagram shows an energy transfer as a flowing arrow whose width is proportional to the amount of energy. The input enters as one wide arrow, and it splits into branches: the useful output carries on in the main direction, and the wasted energy bends away, usually downwards. Because energy is conserved, the widths of the branches always add up to the width of the input. For the motor above, a 500 J arrow splits into a 350 J useful branch and a 150 J wasted branch.
Reading a Sankey diagram means reading the widths. If the diagram is drawn on a grid with each square standing for 10 J, an input 20 squares wide is 200 J; a useful branch 5 squares wide is 50 J; the wasted branch must therefore be 15 squares, 150 J, and the efficiency is 50 ÷ 200 = 0.25, or 25%.
Many real transfers happen in several stages, and a Sankey diagram can show each stage in turn. In a coal-fired power station, suppose 1000 MJ of chemical energy enters the boiler. The boiler loses 150 MJ by heating the surroundings and passes 850 MJ to the steam. The turbine loses 450 MJ, mostly in the hot steam that leaves it, and passes 400 MJ to the generator as kinetic energy. The generator loses 40 MJ by heating and delivers 360 MJ of electrical energy. On the diagram the arrow narrows at every stage, with a wasted branch peeling off each time.
The overall efficiency compares the final useful output with the very first input: 360 ÷ 1000 = 0.36, or 36%. Check it with conservation: the three wasted branches, 150 + 450 + 40 = 640 MJ, plus the 360 MJ output make 1000 MJ, the input. The stage with the biggest loss, here the turbine, is where improvements would make the most difference.
Worth remembering
- Sankey diagram: arrow width ∝ energy; the branches add up to the input.
- Multi-stage: a wasted branch leaves at each stage, and the arrow narrows.
- Overall efficiency = final useful output ÷ first input.
Worked example
A motor receives 500 J and provides 350 J of useful work: efficiency = 350/500 = 70%.
Account for every joule
Change a value and watch the readings follow. Open it on the lab stage
Account for every joule
Of the 500 J put in, 350 J is useful and 150 J is wasted, heating the surroundings.
- Useful output
- 350 J
- 70% × 500 J
- Wasted output
- 150 J
- 500 J − 350 J
Goal
Follow every joule into a device and out again, and work out how efficient the device is.
Predict, where you are
If Ithe, thewill
Say what you expect before you move anything. Check makes the change for you.
Test, still to come
Change one thing at a time and watch the readings. The notebook keeps a reading each time you record one.
Explain, still to come
After you check a prediction, this says why it happened.
Try this · 0 of 3
- Set 50% and check that the useful and wasted outputs add up to the input., not yet
- Keep 500 J going in and find the efficiency that gives 400 J of useful output., not yet
- A device wastes 75 J of every 250 J it takes in. Work out its efficiency, then set it up to check., not yet
efficiency = useful energy output ÷ total energy input × 100%
350 J ÷ 500 J × 100% = 70%
Investigation notebook · 0 readings
Change one variable at a time and record the results. These readings stay here until you leave this lesson or reset the notebook.
About this model
Energy-flow widths are proportional to energy, at one scale for every setting, with no uncounted input.
Practice
Warm-up · not marked
Check your understanding
Answer in your own words, then compare with the worked answer. Nothing here is saved or scored.
Worked answer
Useful = 0.8 × 250 = 200 J; wasted = 50 J.
Check your method, units and explanation against it.
Marked practice